• https://www.langdonparkatwestcovina.com/
  • Mbokslot
  • https://data.pramukajabar.or.id/
  • http://103.206.170.246:8080/visi/
  • https://siakad.stkippgri-bkl.ac.id/
  • https://lms.rentas.co.id/
  • https://siakad.stkippgri-bkl.ac.id/pengumuman
  • https://yahooo.co.com/
  • https://smartgov.tapinkab.go.id/method
  • https://sptjm.lldikti4.id/banner/
  • mbokslot
  • https://ikom.unismuh.ac.id/
  • https://ppm-rekrutmen.com/antam/
  • https://sptjm.lldikti4.id/storage/
  • https://www.langdonparkatwestcovina.com/floorplans
  • https://silancar.pekalongankota.go.id/newsilancar/
  • https://app.mywork.com.au/login
  • https://dms.smhg.co.id/assets/js/hitam-link/
  • https://smartgov.bulelengkab.go.id/image/
  • https://rsupsoeradji.id/
  • slotplus777
  • https://ibs.rshs.or.id/operasi.php
  • https://www.saudi.dccisummit.com/agenda/
  • Mbokslot
  • http://103.81.246.107:35200/templates/itax/-/mbok/
  • https://alpsmedical.com/alps/
  • https://pastiwin777.cfd/
  • https://elibrary.rac.gov.kh/
  • https://heylink.me/Mbokslot.com/
  • https://sman2situbondo.sch.id/
  • https://www.capitainestudy.fr/quest-ce-que-le-mba/
  • Interactive Fire Control Panel IFS7002 – one signal loop – Royal Fire Protection

    Royal Fire Protection

    Interactive Fire Control Panel IFS7002 – one signal loop

    Interactive Fire Control Panel IFS 7002 is an up-to-date, high reliable, multi-functional and versatile device, providing the user with unexpected potential in the design, installation and operation of addressable fire alarm systems.

    TECHNICAL DATA:

    Physical configuration:
    – 1 fire alarm loops
    – 2 monitored outputs
    – 1 relay outputs for fire condition
    – 1 programmable relay outputs for fire condition
    – 1 relay output for fault conditions

    Fire alarm zones:
    – Maximum number of zones – 64
    – Maximum number of fire detectors and in-out devices – 60

    Fire alarm loops:
    – Maximum number of fire detectors in a loop – 125
    – Connecting line – two-wire shielded
    – Maximum resistance of a loop – 100
    – Output resistance of a loop – 20
    – Maximum consumption of a loop – 200mA

    Monitored outputs: – 2 pcs
    – Type – potential
    – Еlectrical characteristics – (24±5)V/0,5A

    Relay output for fire conditions – 1 pc
    – Type – potential free, switching
    – Electrical characteristics – 3A/125VAC; 3A/30VDC

    Relay (programmable) output for fire conditions – 1 pc
    – Type – potential free, switching
    – Electrical characteristics – 3A/125VAC; 3A/30VDC

    Relay output for fault conditions – 1 pc
    – Type – potential free, switching
    – Electrical characteristics – 3A/125VAC; 3A/30VDC

    Performance:
    – Control over fire alarm loops and monitored outputs for fault conditions (short circuit and interruption) and automatic reset
    – Dedicated led indication per fire zone
    – Detection of removed devices in the loops and automatic reset
    – Ability to set the zones in Coincidence Mode
    – Two phases of Fire condition, programmable time for Fire condition stage I, separately for each zone
    – Option to prolong the time period for Fire condition stage I with programmable inspection period, specified for each zone
    – Built-in sounder for fire condition – one tonal, discontinuous, can be switched off
    – Built-in sounder for fault condition – one tonal, discontinuous, can be switched off
    – Built-in real time clock
    – Set of test modes and options for adjustment

    – Setting the clock:
    – Check ups on light and sound indications
    – Test of fire alarm zones
    – Adjustment of outputs and integrated external devices
    – Programming of parameters and modes of operation
    – Remote programming of the parameters from distant operator control point

    – Energy independent event log of registered events with the events type, date and hour – up to 1023 events
    – Interfaces for communication with external devices – CAN 2.0B and USB.

    Indications of registered events:
    – Light indication – LED
    – Text messages – LCD display, 320 х 240 points, backlit
    – Sound signaling – built-in sounder

    Power supply:
    Mains:
    – voltage – 220/230V
    – frequency – 50Hz

    Back up batteries:
    – battery type – lead, gel electrolyte
    – number of batteries – 2 pcs
    – connection – serial connection
    – nominal voltage of the back up battery – 2x12V DC
    – nominal capacity C20 – 7Ah
    – charge voltage – 28V

    Consumption on back up batteries supply:
    – at 24V – <160mA
    – at 26V – < 150mA

    Power supply to external devices:
    – Voltage – (24±5)V
    – Maximum current value (including current of monitored outputs) – 1А

    Dimensions:
    – Overall dimensions – 286 x 148 x 125 mm
    – Weight (batteries not included) – 1.240 kg.